Model
|
VDV30 |
VDV31 |
Pressure gas needle valve VNV
Introduction
• Live-loaded packing system
• Vee stem, regulating stem, soft-seat stem are optional
• Compact design
• Panel mounting
• Straight, angle, and cross flow patterns
• Working presssure up to 5000 psig (345 bar)
Application
• Component Testing
• Calibration Systems
• Laboratory Pressure Control
• High Pressure Sampling Systems
• Service & Test Equipment
Technical parameters
| Type | Needle valve |
|
| Inlet pressure P1 | max. 345 bar | |
| Materials | ||
| Body | see ordering info | |
| Seat | PCTFE | |
| Filter | 316 | |
| Inlets / Outlets | see ordering info | |
| Temperature range | -54℃ to +232℃ | |
| Leak rate | 0.1 cc/min | |
| Orifice | see ordering info | |
| Weight | 0.1kg | |
Product picture



Pressure gas needle valve VSNV
Introduction
• Needle Valves
• Flow control, on/off valve
• Brass plating material, aluminum alloy handwheel
• Working pressure Max. 67bar (1000psig)
• Ultrasonic cleaning, degreasing treatment
• Tested for use with oxygen
Application
• Component Testing
• Calibration Systems
• Laboratory Pressure Control
• High Pressure Sampling Systems
• Integrated equipment set
Technical parameters
| Type | Needle Valves |
|
| Working Pressure | Max. 67 bar | |
|
Materials |
||
| Body | Chrome Plated Brass | |
| Sealing | Rigidity Seal | |
| Temperature range | -54℃ to +74℃ | |
| Weight |
0.1kg |
|
Simplified Explanation
In simple terms: A "precision flow control valve" designed to regulate gas flow at high pressure, using a needle-like stem that gradually adjusts the opening to control the flow rate. Think of it as a finely-tuned faucet, giving you perfect control over how much gas flows through your system, all while withstanding high pressures and ensuring no leaks.
- High Pressure Resistance: Maximum working pressure of 345 bar (about the pressure you'd encounter at a depth of 3,450 meters underwater).
- Precise Control: The needle valve's fine-thread stem allows for accurate adjustment of gas flow, ideal for applications requiring subtle, consistent flow rates.
- Flexible Connections: Available with multiple NPT connection sizes (1/8, 1/4, 3/8, 1/2), so you can match it to your system's requirements.
- Leak-Proof: Designed with tight sealing mechanisms to prevent gas leaks and ensure safety in high-pressure environments.
Analogy: Think of it like a precision ink pen-small adjustments with the needle stem let you control the flow with high accuracy, just like writing in fine detail.
- Gas Cylinder Management: Ideal for controlling gas flow in cylinders with pressures up to 345 bar, such as in hydrogen, nitrogen, or oxygen storage systems.
- Industrial Systems: Used to precisely regulate gas flow in machinery or systems requiring high-pressure gas delivery with consistent flow rates.
- Chemical Processing: Ensures accurate flow control in chemical systems where precise regulation is critical, particularly when dealing with non-corrosive gases.
- Laboratories: Perfect for applications where high-purity gases need to be controlled with pinpoint accuracy, ensuring no contamination or excess flow.
Two operation modes:
- Handwheel Version:
- Suitable for: Situations that require fine control over flow rate (like in laboratories or testing environments).
- Operation: Rotate the handwheel to move the needle stem, adjusting the flow of gas in precise increments.
- Lever Version:
- Suitable for: Scenarios where quick adjustments are needed (like in industrial setups).
- Operation: Pull the lever to open or close the valve, allowing for more immediate changes in flow rate.
- Direction matters: Always ensure the valve is installed in the correct flow direction, which is marked on the valve body.
- Connection matching: Make sure the connection size (e.g., 1/8, 1/4, 3/8, 1/2 NPT) fits your system. Use sealing tape if necessary to prevent leaks.
- Regular inspection: Needle valves are subject to wear over time, especially the needle stem. Check periodically for any signs of damage or leakage.
Issue 1: Valve not sealing properly (leakage)
Cause: Worn seals or damage to the valve stem.
Solution: Replace the seals or stem, and ensure the valve is free of any debris or impurities.
Issue 2: Difficulty adjusting the handwheel/lever
Cause: Lack of lubrication or excessive pressure buildup.
Solution: Release internal pressure and lubricate the valve stem for smoother operation.
Issue 3: Flow not adjustable or erratic
Cause: Needle stem becoming clogged or misaligned.
Solution: Clean the needle stem and ensure it is correctly aligned for smooth flow control.
Issue 4: Connection leakage
Cause: Improper threading or incorrect sealing.
Solution: Recheck the NPT connection and apply sealing tape where necessary to ensure a tight fit.
Hot Tags: pressure gas needle valve, China pressure gas needle valve manufacturers, suppliers, Low Pressure High Flow Regulator, Stainless Steel Gas Ball Valve, Calibration Gas Regulators, hp accessories, UHP Diaphragm Valve, Pressure Control Panels